The operating parameters include commonly used adjustment parameters for equipment operation. The parameter directly affects the running function and the running effect of the whole machine, please adjust it carefully.
1.Sealing film delay
The time that the sealing knife stays in the sealing area. When the film is thicker or needs to be heated for a longer time, the delay can be lengthened. When the delay is set to 0, or when the speed is relatively slow, the sealing knife passes through the sealing area at a constant speed. When the running speed is relatively fast, the sealing knife will decelerate before entering the sealing area to ensure that the time of staying in the sealing area is approximately equal to the sealing film delay setting time.
2.Pull film delay
3.Cylinder delay
Longitudinal sealing cylinder delay:The length of time for the vertical sealing cylinder to act after the film is drawn. When the vertical sealing is not good, the cylinder delay can be appropriately lengthened, but note that too long a time length will affect the film pulling action in the next cycle, and it should be adjusted according to the actual situation.
4. Quantitative shutdown function
When the quantitative shutdown parameters are set, the equipment will count the number of packages that have been produced, and will stop the equipment when the quantitative shutdown quantity is reached.
The remaining number of quantitative shutdowns will appear on the operation page, and the statistics of quantitative shutdowns are independent of the cumulative output. Stopping the equipment during the production process does not affect the number statistics, and will continue to count when restarting