News

DET14A digital aluminum foil metal detector Work mode setting(1)

Datetime: 2022-07-26    Visit: 35

1.Working mode setting status, see Picture 1


Picture 1

A. Self-stop after testing (D)

     This mode stops when the instrument detects the iron content and then waits for operation.

B. Return to stop after detection,See Picture 2

Picture 2

In this mode, when the instrument detects the iron content, the motor sends back the object to stop,

Then wait for the operation.To start, you must press to start the key.

  C. Return to self-startup after detection (F)see Picture 3

         In this mode, when the iron content detects by the instrument, the motor goes back to the inspected object, stops for 2 seconds, and then is automatically starts.To stop, you must press to start and stop the key.